QSC AD-S6T-BK/WH

ad-s6t-bkwh
ติดต่อสอบถาม Manufacturer: QSCQSC

รายละเอียดย่อ :
ลำโพง Two-way, 6.5" Surface Mount, Weather-resistant,Foreground/Background Loudspeaker with 70/100V transformer & 8Ω bypass, includes mounting hardware, Available in black or white.
รายละเอียดทั้งหมด :

 

QSC AD-S6T-BK/WH ลำโพง Two-way, 6.5" Surface Mount, Weather-resistant,Foreground/Background Loudspeaker with 70/100V transformer & 8Ω bypass, includes mounting hardware, Available in black or white.

Features

  • 6” weather treated woofer; 1” silk dome tweeter
  • 105° Axisymmetric (conical) coverage
  • 60 watt low-saturation and low-loss 70/100V transformers with 8Ω bypass
  • Maximum peak SPL 116 dB (8 ohm bypass)
  • DMT™ (Directivity Matched Transition) ensures smooth, uniform frequency response over the coverage area
  • X-Mount™ system  enables the loudspeaker to be easily installed and deployed at a variety of angles with no slippage over time
  • Advanced voicing filter sets using QSC Intrinsic Correction™, available through either Q-Sys processing or CXD amplifier platforms
  • Lightweight ABS enclosures offer long-term durability and lasting good looks
  • Sealed input panel cover and powder coated aluminum grilles for added weather resistance
  • Meets IEC60529 IP-54 for dust and splash resistance
  • Available in black (RAL 9011) or white (RAL 9010)
  • Complete EASE, CF2, CAD, and BIM information available online

Specsheet

https://drive.google.com/file/d/1B6yvV-Rff9tDj3qxPTy0Rkbs2vUe3Xkt/view?usp=sharing

 

Specifications

System Details AD-S6T AD-S8T AD-S10T
Effective frequency range1 60 Hz to 20 kHz 55 Hz to 20 kHz 50 Hz to 19 kHz
Rated noise power / voltage2 150 watts / 35 volts (rms) 200 watts / 40 volts (rms) 250 watts / 45 volts (rms)
Broadband sensitivity3 89 dB SPL 90 dB SPL 92 dB SPL
Coverage angle (-6 dB) 105° 105° 90°
Directivity factor (Q) 5 7 10
Directivity Index 7 dB 9 dB 10 dB
Maximum continuous SPL4 110 dB 113 dB 116 dB
Maximum peak SPL4 116 dB 119 dB 122 dB
Rated impedance 8 ohms 8 ohms 8 ohms
Recommended amplifier power (loudspeaker "program" power) 300 watts 400 watts 500 watts
Transformer taps 70 V: 60, 30, 15, 7.5 W and 8Ω bypass 70 V: 60, 30, 15, 7.5 W and 8Ω bypass 70 V: 100, 50, 25, 12.5 W and 8Ω bypass
100V: 60, 30, 15 W and 8Ω bypass 100V: 60, 30, 15 W and 8Ω bypass 100V: 100, 50, 25 W and 8Ω bypass
HF transducer 1” silk dome tweeter / 1” voice coil, horn loaded 1” exit / 1.4” voice coil compression driver 1” exit / 1.4” voice coil compression driver
LF transducer 6” weather resistant paper cone woofer 8” weather resistant paper cone woofer 10” weather resistant paper cone woofer
1.5” / 38 mm voice coil 2” / 51 mm voice coil 2.5” / 64 mm voice coil
Input connector type Euroblock connector with parallel output Euroblock connector with parallel output terminals Euroblock connector with parallel output terminals
Enclosure material Painted ABS polymer Painted ABS polymer Painted ABS polymer
Grille material Powder coated aluminum Powder coated aluminum Powder coated aluminum
X-Mount material Powder coated aluminum Powder coated aluminum Powder coated aluminum
Enclosure Details
Ingress protection IP-54 IP-54 IP-54
Operating environment Designed for indoor and outdoor use Designed for indoor and outdoor use Designed for indoor and outdoor use
Testing The AD Series loudspeakers qualified for outdoor use using the following tests: The AD Series loudspeakers qualified for outdoor use using the following tests: The AD Series loudspeakers qualified for outdoor use using the following tests:
Salt fog: MIL-STD-810G Method 509.5 for 100 hrs. Salt fog: MIL-STD-810G Method 509.5 for 100 hrs. Salt fog: MIL-STD-810G Method 509.5 for 100 hrs.
Humidity: MIL-STD-810G Method 507.5, Natural cycle B2, cyclic high RH for 7 days Humidity: MIL-STD-810G Method 507.5, Natural cycle B2, cyclic high RH for 7 days Humidity: MIL-STD-810G Method 507.5, Natural cycle B2, cyclic high RH for 7 days
High and low temperature: tested to QSC internal standards between -20° and 50° C High and low temperature:  tested according to QSC internal standards between -20° and 50° C High and low temperature:  tested according to QSC internal standards between -20° and 50° C
Operating Temperature Range -20 to 50° C / -4 to 122° F -20 to 50° C  / -4 to 122° F -20 to 50° C  / -4 to 122° F
Net weight 13.6 lb / 6.2 kg 24.1 lb / 11 kg 31 lb / 15 kg
Product dimensions 14.4” × 8.5” × 8.5” (365 × 215 × 215 mm) 17.3” × 10” × 9.9” (440 × 254 × 251 mm) 20.3” × 12.5” × 11.7” (516 × 318 × 298 mm)
Shipping weight 33.4 lb / 15.2 kg (pair packed) 32.1 lb / 14.5 kg 40.6 lb / 18.45 kg
Shipping dimensions 20" × 12” × 23” (510 × 305 × 585 mm) (pair packed) 24.3 × 13.8” × 13.8” (729 × 351 × 351 mm) 31.7” × 16.1” × 16.1” (805 × 409 × 409 mm)
Included accessories X-Mount mounting system, euroblock connector,
input panel cover
X-Mount mounting system, euroblock connector, input panel cover X-Mount mounting system, euroblock connector, Input panel cover
Optional accessories   YMS8T yoke mount, M10 Kit-C YMS10T yoke mount, M10 Kit-C
  1 Free-field, -10 dB from on-axis sensitivity 1 Free-field, -10 dB from on-axis sensitivity 1 Free-field, -10 dB from on-axis sensitivity
  2 IEC60268-1 noise signal for 2 hours 2 IEC60268-1 noise signal for 2 hours 2 IEC60268-1 noise signal for 2 hours
  3 On-Axis, free-field sensitivity, 2.83V, 1 m 3 On-Axis, free-field sensitivity, 2.83V, 1 m 3 On-Axis, free-field sensitivity, 2.83V, 1 m
  4 Calculated from rated noise voltage and sensitivity 4 Calculated from rated noise voltage and sensitivity 4 Calculated from rated noise voltage and sensitivity